Specifications
Parameters Unit Values
Stage    Single Stage Dual Stage
Signal Wavelength Range nm 1530~1565
Pump Wavelength Range nm 960~990 or 1460~1490
Max. Signal Insertion Loss (Input to Output) dB 1.1(for 1%), 1.2(for 2%),1.3(for 5%), 1.5(for 10%), 4.2(for 50%) 1.2(for 1%), 1.3(for 2%),1.4(for 5%), 1.6(for 10%), 4.3(for 50%)
Max. Pump Insertion Loss (Pump Channel) dB 0.5    
Signal Tap Ratio( Input to Tap) % 1+/-0.2, 2+/-0.4, 5+/-1, 10+/-2, 50  
Typ. Signal Peak Isolation (Output to Input) dB 40 55
Min. Signal Isolation at 23≧; all polarization states dB 30  48   
Min. Directivity (Pump to Tap) dB 50  
Min.Extinction Ratio (Input to Output, only for F-type) dB 23  
Min.Extinction Ratio (Input to Output, only for B-type) dB 20  
Min. Return Loss (for all ports) dB 50  
Max. Optical Power (CW) mW 500  
Max. Tensile Load N 5  
Fiber Type   PM 1550 Panda Fiber for Input and Output Ports, SMF-28e Fiber for Tap Port, HI 1060(980nm Pump) or SMF-28e(for 1480nm Pump) Fiber for Pump Port
Operating Temperature ≧ 0 to +70  
Storage Temperature ≧ -40 to +85  
      
*Above specifications are for device without connector.    
*For devices with connectors, IL will be 0.3dB higher, RL will be 5dB lower,ER will be 2dB lower.    
*The PM fiber and the connector key are aligned to the slow axis.    
      
Package Dimensions    
 
Ordering Information  
PMTIWDM-�戡�-��-��-∠∠-⊥-⌒⌒⌒⌒-∂∂∂∂-∇  
     
�戡�: Pump Type             ⊥: Axis Alignment ∇: Fiber Length
 98 - 980nm              F - Fast Axis Blocked   0.8 - 0.8m  
 48 - 1480nm              B - Both Axis Working   S - Specify     
   
��: Pump Direction      
 F - Forward Pump      
 B - Backward Pump (only for Fast Axis Blocked)    
              ⌒⌒⌒⌒: Connector Type on Port 1, 2, 3 & 4    
��: Stage              1 - FC/UPC     
 S - Single Stage              2 - FC/APC  
 D - Dual Stage              3 - SC/UPC  
               4 - SC/APC    
∠∠: Tap Ratio              N - None      
 01 - 1%
             S - Specify
 
 02 - 2%                     
 05 - 5%             ∂∂∂∂: Fiber Jacket on Port 1, 2, 3 & 4  
 10 - 10%              B - 250um Bare Fiber  
 50 - 50%              L - 900um Loose Tube         
 SS - Specify              S - Specify