Fiber Optical components

Fiber Optical components - Products
Fiber Optical components - Picture
  Download PDF
                    PM Tap Isolator WDM Hybrid
¡¡¡¡
Features¡¡ Applications¡¡
Input Signal Power Monitoring EDFAs¡¡
Pump / Signal Multiplexing Fiber Lasers¡¡
Low Insertion Loss ¡¡ Fiber Optical Test Equipment
Low Cost
High Extinction Ratio
¡¡¡¡
Specifications
Parameters Unit Values
Stage¡¡   Single Stage Dual Stage
Signal Wavelength Range nm 1530~1565
Pump Wavelength Range nm 960~990 or 1460~1490
Max. Signal Insertion Loss (Input to Output) dB 1.1(for 1%), 1.2(for 2%),1.3(for 5%), 1.5(for 10%), 4.2(for 50%) 1.2(for 1%), 1.3(for 2%),1.4(for 5%), 1.6(for 10%), 4.3(for 50%)
Max. Pump Insertion Loss (Pump Channel) dB 0.5    
Signal Tap Ratio( Input to Tap) % 1+/-0.2, 2+/-0.4, 5+/-1, 10+/-2, 50  
Typ. Signal Peak Isolation (Output to Input) dB 40 55
Min. Signal Isolation at 23¡æ; all polarization states dB 30¡¡ 48¡¡ ¡¡
Min. Directivity (Pump to Tap) dB 50  
Min.Extinction Ratio (Input to Output, only for F-type) dB 23  
Min.Extinction Ratio (Input to Output, only for B-type) dB 20  
Min. Return Loss (for all ports) dB 50  
Max. Optical Power (CW) mW 500  
Max. Tensile Load N 5  
Fiber Type   PM 1550 Panda Fiber for Input and Output Ports, SMF-28e Fiber for Tap Port, HI 1060(980nm Pump) or SMF-28e(for 1480nm Pump) Fiber for Pump Port
Operating Temperature ¡æ 0 to +70  
Storage Temperature ¡æ -40 to +85  
¡¡¡¡ ¡¡ ¡¡
*Above specifications are for device without connector. ¡¡ ¡¡
*For devices with connectors, IL will be 0.3dB higher, RL will be 5dB lower,ER will be 2dB lower. ¡¡ ¡¡
*The PM fiber and the connector key are aligned to the slow axis. ¡¡ ¡¡
¡¡¡¡ ¡¡ ¡¡
Package Dimensions ¡¡ ¡¡
¡¡
Ordering Information ¡¡
PMTIWDM-¢Ù¢Ù-¢Ú-¢Û-¢Ü¢Ü-¢Ý-¢Þ¢Þ¢Þ¢Þ-¢ß¢ß¢ß¢ß-¢à ¡¡
¡¡ ¡¡ ¡¡
¢Ù¢Ù: Pump Type             ¢Ý: Axis Alignment ¢à: Fiber Length
 98 - 980nm              F - Fast Axis Blocked   0.8 - 0.8m ¡¡
 48 - 1480nm              B - Both Axis Working   S - Specify    ¡¡
¡¡ ¡¡
¢Ú: Pump Direction      
 F - Forward Pump      
 B - Backward Pump (only for Fast Axis Blocked)    
              ¢Þ¢Þ¢Þ¢Þ: Connector Type on Port 1, 2, 3 & 4    
¢Û: Stage              1 - FC/UPC  ¡¡ ¡¡
 S - Single Stage              2 - FC/APC ¡¡
 D - Dual Stage              3 - SC/UPC ¡¡
¡¡              4 - SC/APC   ¡¡
¢Ü¢Ü: Tap Ratio              N - None  ¡¡¡¡ ¡¡
 01 - 1%
             S - Specify
¡¡
 02 - 2%                  ¡¡ ¡¡
 05 - 5%             ¢ß¢ß¢ß¢ß: Fiber Jacket on Port 1, 2, 3 & 4 ¡¡
 10 - 10%              B - 250um Bare Fiber ¡¡
 50 - 50%              L - 900um Loose Tube    ¡¡ ¡¡ ¡¡
 SS - Specify              S - Specify ¡¡ ¡¡ ¡¡